<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-25 00-44-38
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 66 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.1 kHz -20 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 19020 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,7 dBr 1,87 dBr 2,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"InTime Quintet, Tampere Filharmonia, Marcelo Jaime Nisinman (ban"
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2025/05/25 0.43.34 Total samples: 19020 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 2,9 dBr MIN: -0,7 dBr AVE: 1,87 dBr % above 12,2 dBr: 0,0 Last value: 2,5 dBr (2025/05/25 0.43.33) 00.30 00.32 00.34 00.36 00.38 00.40 00.42 -1 0 1 2 3 Pm [dBr]